Computational Fluid Dynamics (CFD) Blog - LEAP Australia & New Zealand. Posted By LEAP CFD Team on Jan 1. It is important to remember that your solution is the numerical solution to the problem that you posed by defining your mesh and boundary conditions. The more accurate your mesh and boundary conditions, the more accurate your . For a Steady State simulation we need to ensure that the solution satisfies the following three conditions: - Residual RMS Error values have reduced to an acceptable value (typically 1. Monitor points for our values of interest have reached a steady solution- The domain has imbalances of less than 1%.
RMS Residual Error Values. Our values of interest are essentially the main outputs from our simulation, so pressure drop, forces, mass flow etc. We need to make sure that these have converged to a steady value otherwise if we let the simulation run for an additional 5. Ensuring that these values have reached a steady solution means that you are basing your decisions on a single repeatable value. Example of Monitoring a Value of Interest.
As a rule, we must ensure that prior to starting a simulation we clearly define what our values of interest are, and we make sure that we monitor these to ensure that they reach a steady state. As previously highlighted, we also need to make sure that the Residual RMS Error values are to at least 1.
ANSYS has pioneered the development and application of simulation methods to solve the most challenging product engineering problems. Applied to design concept, final-stage testing, validation and trouble-shooting existing. ANSYS Remote Solve Manager User's Guide ANSYS, Inc. Southpointe 275 Technology Drive Canonsburg, PA (T) (F) ANSYS Release 15.0 November. ANSYS ICEM CFD Tutorial Manual ANSYS, Inc. Southpointe 275 Technology Drive Canonsburg, PA 15317 [email protected] http:// (T) 724-746-3304 (F) 724-514-9494 ANSYS ICEM CFD 14.0 November 2011 ANSYS, Inc.
Finally, we need to ensure that the overall imbalance in the domain is less than 1% for all variables. Imbalances in the Domain. MESH INDEPENDENCE STUDYThe approach outlined above results in a single solution for the given mesh that we have used.
Although we are happy that this has . Not checking this is a common cause of erroneous results in CFD, and this process should at least be carried out once for each type of problem that you deal with so that the next time a similar problem arises, you can apply the same mesh sizing. In this way you will have more confidence in your results. The way we carry out a mesh independence study is fairly straight forward.- Step 1. Run the initial simulation on your initial mesh and ensure convergence of residual error to 1.
If not refine the mesh and repeat.- Step 2. Once you have met the convergence criteria above for your first simulation, refine the mesh globally so that you have finer cells throughout the domain.
All pages manually coded in PHP/MySQL & HTML/CSS with a text editor utilizes (possibly valid) HTML 4.01, CSS 2.0, RSS 2.0, and OpenSearch 1.1 please note that this site makes use of cookies site created & maintained by sheldon. Target Rock welders can provide a unique level of expertise. Experience includes working with stainless steel, low and high alloy, nickel and copper base. Type of Welding: Shielded Metal Arc; Gas Tungsten Arc (manual. A 1RC equivalent circuit model is used in this.
Generally we would aim for around 1. Run the simulation and ensure that the residual error drops below 1. At this point you need to compare the monitor point values from Step 2 against the values from Step 1. If they are the same (within your own allowable tolerance), then the mesh at Step 1 was accurate enough to capture the result.
If the value at Step 2 is not within acceptable values of the Step 1 result, then this means that your solution is changing because of your mesh resolution, and hence the solution is not yet independent of the mesh. In this case you will need to move to Step 3.- Step 3. Because your solution is changing with the refinement of mesh, you have not yet achieved a mesh independent solution. You need to refine the mesh more, and repeat the process until you have a solution that is independent of the mesh. You should then always use the smallest mesh that gives you this mesh independent solution (to reduce your simulation run time).- Example.
The best way to check for a mesh independent solution is to plot a graph of the resultant monitor value vs the number of cells in your simulation. This is illustrated below where we have three results from our steady monitor points for the average temperature at an outlet. We can see that with 4 million cells we have a result, which could be . By increasing the mesh resolution to 6 million cells, we can see that there has been a jump in the value of interest that is not within my user specified tolerance (in this example I'll say +/- 0. By increasing the mesh size further we can see that the 8 million cell simulation results in a value that is within my acceptable range. This indicates that we have reached a solution value that is independent of the mesh resolution, and for further analysis we can use the 6 million cell case, as it will give us a result within the user defined tolerance.